• Iacs Approved Explosion Proof Marine Ballast Water Management System Bwms
  • Iacs Approved Explosion Proof Marine Ballast Water Management System Bwms
  • Iacs Approved Explosion Proof Marine Ballast Water Management System Bwms
  • Iacs Approved Explosion Proof Marine Ballast Water Management System Bwms
  • Iacs Approved Explosion Proof Marine Ballast Water Management System Bwms
  • Iacs Approved Explosion Proof Marine Ballast Water Management System Bwms

Iacs Approved Explosion Proof Marine Ballast Water Management System Bwms

After-sales Service: World Wide
Warranty: 1 Year
Application: Ships
Disinfection Method: Ultraviolet
Standard: Imo Mepc300(72)
Capacity: 50-3000m3/H
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Chongqing, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 30 days
to see all verified strength labels (10)

Basic Info.

Model NO.
GH
Sterilization
UV
Chemical
Free
Function
Ballast Water Treatment
Core Components
UV Reactor, Filter, Sensors, Sampling Devices
Advantage
Full Automatic/No Contamination
Installation
Free
Commissioning
Free
Transport Package
Plywood Box
Trademark
GH
Origin
China
Production Capacity
120 PCS/Month

Product Description

Iacs Approved Explosion Proof Marine Ballast Water Management System BwmsProduct Introduction

IACS Approved Explosion Proof Marine Ballast Water Management System BWMS uses advanced full-automatically backwash filter, with high-efficient medium-pressure UV radiation technology to accomplish the online treatment of ship ballast water. LS BWMS has been type approved in accordance with MEPC.300(72) aka new G8 and BWMS Code by China Classification Society (CCS) and fully meet "D-2" discharge standard.

IACS Approved Explosion Proof Marine Ballast Water Management System BWMS offers simple operation and simple maintenance, dual-directional (local and remote) automatic control, friendly interface, and easy manipulation. The system is in unit-modular design with a capacity range from 150~3000m³/h, thus providing flexible and simple installation on small tonnage vessels while multiple units assembled installation on large-tonnage vessels. Therefore, it takes no large space. Meanwhile, the system is also suitable for old ships with narrow space.

The filtration plus UV radiation method takes no additional contamination with no adding or reserving chemicals. The entire system is completely closed in operation thus causing no hazards of radiation or noise to the crew.

System control can be realized through the optional remote control box for local and remote two-way control. Meet on-site and remote operation. The whole process is convenient, intuitive and reliable. The system working data can be stored and recorded to reflect the operation of the equipment during the ship's voyage, and can provide working operation records according to the requirements of the inspection department, with long-term traceability.

Iacs Approved Explosion Proof Marine Ballast Water Management System Bwms

Working Principle

The System includes Filter, UV Reactor, Control Unit, Power Cabinet, and Electric Valves, monitoring equipment, sampling device and pipeline. General working modes include ballasting and de-ballasting processes, as well as ballast stripping and emergency bypass.

Working Conditions

Working Conditions

Humidity

0~95%

(Equipment in Engine Room)

Ambient temperature

0~55 ºC

Seawater temperature

0~35 ºC

Slope & Swing

Static

 All directions ≤22.5°

Dynamic

 All directions ≤22.5°

Electromagnetic

Compatibility

Voltage floating

±10%

Instantaneous voltage floating

±20%

Frequency floating

±5%

Instantaneous frequency floating

±10%

(Recover in 3 seconds)

Power Supply

380(440)V, 50(60)Hz, 3Φ

Fresh Water

About 2.0 m3 / time

For replacing seawater in BWMS when storage

General Requirement of Relevant Piping

Shipbuilding standard are mandatory regarding relevant piping, sampling facilities and pipes used along for firefighting, and shall be easy to clean, inspect, service and operate. The freshwater piping shall not be mixed up with seawater and piping design pressure shall not exceed 1.0MPa.

Electrical

Requirements

The cable connected to the system shall be approved marine cable.

 

Main Model List

 

Model Rated Capacity (m3/h) Capacity Range (m3/h) Power (KW) Weight (Ton) Length (mm) Width (mm) Height (mm)
BWS-150 150 50-150 22 1.5 2600 1000 1700
BWS-250 250 150-250 26 2.2 2400 2100 1800
BWS-350 350 250-350 35 2.3 2400 2100 1900
BWS-500 500 350-500 50 2.4 2400 2100 2000
BWS-850 850 500-850 74 3.0 3100 2400 2300
BWS-1150 1150 850-1150 98 3.3 3500 2500 2300
BWS-1500 1500 1150-1500 123 4.1 4500 3000 2400
BWS-1700 1700 1500-1700 146 5.9 5000 3100 2300
BWS-2300 2300 1700-2300 194 6.5 5500 3800 2300
BWS-3000 3000 2300-3000 243 8.2 6500 4500 2400

 

Automatic Backflush Filter as the first step of the system is specifically designed for ballast water screening, which has fine mesh elements aiming to remove the microbe and sediments with size larger than 50μm.

Filter adopts the up-to-date concept of auto backflush to efficiently fulfill filtering and screen-cleaning at the same time, backflush automatically starts based on differential pressure while filtration continues, with no other manual on-site operations needed.

Filter functions only in Ballasting process while it is bypassed in De-ballasting process and By-pass process.