• 600m3/H Marine Fire Pump and Water Monitor External Fire Fighting 1/4 Fifi System
  • 600m3/H Marine Fire Pump and Water Monitor External Fire Fighting 1/4 Fifi System
  • 600m3/H Marine Fire Pump and Water Monitor External Fire Fighting 1/4 Fifi System
  • 600m3/H Marine Fire Pump and Water Monitor External Fire Fighting 1/4 Fifi System
  • 600m3/H Marine Fire Pump and Water Monitor External Fire Fighting 1/4 Fifi System
  • 600m3/H Marine Fire Pump and Water Monitor External Fire Fighting 1/4 Fifi System

600m3/H Marine Fire Pump and Water Monitor External Fire Fighting 1/4 Fifi System

Certificate: CCS, BV, ABS etc
Capacity: 600-7200m3/H
Pump Capacity: 600-3600m3/H
Fire Monitor Capacity: 300-2400m3/H
Medium: Seawater, Fresh Water, Afff
Material: Stainless Steel, Bronze, Cast Iron etc
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Chongqing, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 30 days
to see all verified strength labels (10)

Basic Info.

Control
Remote Control
Engine
Diesel Engine
Throw Head
70-150m
Throw Rang
70-180m
Transport Package
Plywood Box
Origin
China
HS Code
8424100090
Production Capacity
10 Sets Per Month

Product Description

600m3/H Marine Fire Pump and Water Monitor External Fire Fighting 1/4 Fifi System
600m3/H Marine Fire Pump and Water Monitor External Fire Fighting 1/4 Fifi System



CCS, BV, ABS Approved 600m3/h, 1200m3/h, 2400m3/h marine external fire fighting fifi system is the marine external fire fighting system (FIFI). It is a necessary fire fighting equipment for external fire fighting of rescue ships, fire fighting ships, and oilfield guard ships, tug boats, work boats, patrol ships, maritime ships etc. It generates large flow and high pressure fire fighting water through fire pumps to supply fire-fighting water cannons for effective external fire fighting, and widely used in inland rivers, coastal ports as tugboats, full-time fireboats and offshore platform supply. It is a professional fire extinguishing system used to extinguish ship fires externally.

600m3/H Marine Fire Pump and Water Monitor External Fire Fighting 1/4 Fifi System
600m3/H Marine Fire Pump and Water Monitor External Fire Fighting 1/4 Fifi System


The FI-FI system is including following core components:

1. Fire pump ( It can be driven by independent diesel engine, for above 2400m3/h, we recommend to drive by main engine to save space)

2. Fire monitors (Remote control, 360 degree rotation, jet and fog spray type)

3. Control system

4. Foam propotioner (Optional)

5. Water curtain system (Optional) : The water curtain system flow capacity is calculated according to the protection area of the ships, it can protect the ship from the fire when it is fighting for the fires from the other vessels.

The fire pump sets is composed of fire pump and diesel engine / electric motor, they are installed on a same stainless steel base frame and then installed in the engine room of the ships which is lower than the water level. The fire monitors can be sea water monitor and sea water and foam monitor, they are usually installed on the decks and controlled through control panel in bridge or remote controller.

The FIFI System had passed the Certification of BV, ABS, CCS and DNV. It can be controlled in wheel house through the main panel, and also can be controlled remotely by wireless control unit . The function buttons on panel can be customerized too.

 

Class None Class FiFi 1/2 FiFi I FiFi II FiFi III
Monitors Quantity 2 1 2 2 2 3 4 3 4
Monitor Capacity (m3/hr) 600 1200 600 1200 3600 2400 1800 3200 2400/2500
Pumps Quantity 1-2 1-2 1-2 2 2-4 2 2-4
Total Pump Capacity   (m3/hr) 600 1200 2400 7200 7200 9600 9600/10000
        Throw Length            (m) 85 120 120 180 150 180 150

Throw Height

(m)

45 45 45 110m@70m 70 110m@70m 70
600m3/H Marine Fire Pump and Water Monitor External Fire Fighting 1/4 Fifi System
600m3/H Marine Fire Pump and Water Monitor External Fire Fighting 1/4 Fifi System

 

 

1. Stainless steel 304 and stainless steel 316L material for fifi system fire water monitor.

2. Bronze impeller and stainless steel shaft for fifi pumps

3. Manual operation, electric motor driven and hydraulic driven for fifi monitor.

4. Electric motor and diesel engine driven fifi water pumps for choosing.

5. CCS, BV, ABS, DNV-GL etc certificates for vessel application.

6. The maximum vertical throwing height of seawater fire monitor can reach 80m.

7. Water jet and fog type and flow rate adjustable for different requirements.

8. Side suction top outlet fifi pumps and end suction top outlet fire water pumps for different installation space.

9. 200m remote control distance without block.

10. 360o horizontal rotation with limited switch for remote fifi water monitors.

600m3/H Marine Fire Pump and Water Monitor External Fire Fighting 1/4 Fifi System

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now